The TBM812 is a professional true rms multimeter, packed with features. They include a large 4-digit readout, analogue bargraph, protection to 1000V, splash proof, transient protected to 6.5kV, CATIII 600V protected, an RS232 Interface, holster and LIFETIME warranty!
Software is available separately as Order Code TED16S.
The unit is fully auto-ranging and ranges include DCV, ACV, DC I, AC I, Resistance, Capacitance and Frequency.
General Specifications
Display: 3-4/5 digits 5000 counts LCD display
Update Rate: Digital Data 5 per second nominal
52 Segments Bar-graph 60 per second nominal
AC Sensing: Average sensing
Operating Temperature: 0°C to 45°C
Relative Humidity: Maximum relative humidity 80% for temperature up to 31°C decreasing linearly to 50% relative humidity at 45°C
Storage Temperature: -20°C to 60°C, 80% R.H. (with battery removed)
Pollution degree: 2
Altitude: Operating below 2000m
Temperature Coefficient: Nominal 0.15 (specified accuracy)/°C @(O°C -- 18°C or 28°C -- 45°C), or otherwise specified
Power Supply: Single standard 9V battery NEDA1604, JIS006P or IEC6F22
Power Consumption: 2.6 mA typical
Low Battery: Below approx. 7V
APO Timing: Idle for 17 minutes
Dimension: L186mm x W87mm x H35.5mm; L198mm x W97mm x H55mm with holster
Weight: 340 gm; 430 gm with holster
Accessories: Test leads (pair); Holster; Battery (installed); User''s manual
Technical Specifications
| DC VOLTAGE | |
| Range | Accuracy |
| 50.00 mV | 0.12% + 2d |
| 500.0 mV | 0.06% + 2d |
| 5.000V, 50.00V, 500.0V,1000V | 0.08% + 2d |
NMRR :>60dB @ 50/60Hz
CMRR :>120dB @ DC, 50/60Hz, Rs=1kOhm
Input Impedance: 10MOhm, 16pF nominal
(44pF nominal for 50mV & 500mV ranges)
| AC VOLTAGE | (50Hz--60Hz) |
| Range | Accuracy |
| 50.00mV, 500.0mV, 5.000V, 50.00V, 500.0V, 1000V | 0.5% + 3d |
| | (40Hz--500Hz) |
| 50.00mV, 500.0mV | 0.8% + 3d |
| 5.000V, 50.00V, 500.0V | 1.0% + 4d |
| 1000V | 1.2% + 4d |
| | Up to 20kHz |
| 50.00mV, 500.0mV | 0.5dB* |
| 5.000V, 50.00V, 500.0V | 3dB* |
| 1000V | Unspec''d |
*Specified from 30% to 100% of range
CMRR :>60dB @ DC to 60Hz, Rs=1kOhm
Input Impedance : 10MOhm, 16pF nominal
(44pF nominal for 50mV & 500mV ranges)
| DC CURRENT | | |
| Range | Accuracy | Burden Voltage |
| 500.0µA | 0.2%+4d | 0.15mV/µA |
| 5000µA | 0.2%+4d | 0.15mV/µA |
| 50.00mA | 0.2%+4d | 3.3mV/mA |
| 500.0mA | 0.2%+4d | 3.3mV/mA |
| 5.000A | 0.2%+4d | 0.03V/A |
| 10.00A* | 0.2%+4d | 0.03V/A |
*10A continuous, 20A for 30 seconds max with 5 minutes cool down interval.
| AC CURRENT | 50Hz--60Hz | |
| Range | Accuracy | Burden Voltage |
| 500.0µA | 0.6%+3d | 0.15mV/µA |
| 5000µA | 0.6%+3d | 0.15mV/µA |
| 50.00mA | 0.6%+3d | 3.3mV/mA |
| 500.0mA | 1.0% + 3d | 3.3mV/mA |
| 5.000A | 0.6% + 3d | 0.03V/A |
| 5.00A | 0.6% + 3d | 0.03V/A |
| 10.00A* | 0.6%+3d | 0.03V/A |
| | 40Hz--1kHz | |
| 500.0µA | 0.8%+4d | 0.15mV/µA |
| 5000µA | 0.8%+4d | 0.15mV/µA |
| 50.00mA | 0.8%+4d | 3.3mV/mA |
| 500.0mA | 1.0%+4d | 3.3mV/mA |
| 10.00A* | 0.8%+4d | 0.03V/A |
*10A continuous, 20A for 30 seconds max with 5 minutes cool down interval
| RESISTANCE | |
| Range | Accuracy |
| 50.00Ohm | 0.2% + 6d |
| 500.0Ohm | 0.1% + 3d |
| 5.000kOhm, 50.00kOhm, 500.0kOhm | 0.1% + 2d |
| 5.000MOhm | 0.4% + 3d |
| 50.00MOhm | 1.5% + 5d |
Open Circuit Voltage : < 1.3VDC
(<3VDC for 50Ohm & 500Ohm ranges)
| FREQUENCY | | |
| Function | Sensitivity (Sine RMS) | Range |
| mV | 300mV | 6Hz - 125kHz |
| 5V | 2V | 6Hz - 125kHz |
| 50V | 20V | 6Hz - 20kHz |
| 500V | 80V | 6Hz - 1kHz |
| 1000V | 300V | 6Hz - 1kHz |
| Ohm, Cx, diode | 300mV | 6Hz - 125kHz |
| µA, mA, A | 10% F.S. | 6Hz - 125kHz |
Accuracy: 0.01% + 2d
| CAPACITANCE | |
| Range | Accuracy* |
| 50.00nF | 0.8% + 3d |
| 500.0nF | 0.8% + 3d |
| 5.000µF | 1.0% + 3d |
| 50.00µF | 2.0% + 3d |
| 500.0µF | 3.5% + 5d |
| 9999µF | 5.0% + 5d |
*Accuracies with film capacitor or better
| DIODE TESTER | | | |
| Range | Accuracy Current | Test Circuit (Typical) | Open Voltage |
| 2.000V DC | 1%+1d | 0.8mA | <3.5 |
| AUDIBLE CONTINUITY TEST | |
| Audible threshold | between 20Ohm and 200Ohm |
Fast response time < 100µs